Class SinkConfig.ConversionAction.Builder

java.lang.Object
com.google.protobuf.AbstractMessageLite.Builder
com.google.protobuf.AbstractMessage.Builder<BuilderT>
com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
io.envoyproxy.envoy.extensions.stat_sinks.open_telemetry.v3.SinkConfig.ConversionAction.Builder
All Implemented Interfaces:
com.google.protobuf.Message.Builder, com.google.protobuf.MessageLite.Builder, com.google.protobuf.MessageLiteOrBuilder, com.google.protobuf.MessageOrBuilder, SinkConfig.ConversionActionOrBuilder, Cloneable
Enclosing class:
SinkConfig.ConversionAction

public static final class SinkConfig.ConversionAction.Builder extends com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder> implements SinkConfig.ConversionActionOrBuilder
 ConversionAction is used to convert a stat to a metric. If a stat matches,
 the metric_name and static_metric_labels will be
 used to create the metric. This can be used to rename a
 stat, add static labels, and aggregate multiple stats into a single metric.
 
Protobuf type envoy.extensions.stat_sinks.open_telemetry.v3.SinkConfig.ConversionAction
  • Method Details

    • getDescriptor

      public static final com.google.protobuf.Descriptors.Descriptor getDescriptor()
    • internalGetFieldAccessorTable

      protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
      Specified by:
      internalGetFieldAccessorTable in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • clear

      Specified by:
      clear in interface com.google.protobuf.Message.Builder
      Specified by:
      clear in interface com.google.protobuf.MessageLite.Builder
      Overrides:
      clear in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • getDescriptorForType

      public com.google.protobuf.Descriptors.Descriptor getDescriptorForType()
      Specified by:
      getDescriptorForType in interface com.google.protobuf.Message.Builder
      Specified by:
      getDescriptorForType in interface com.google.protobuf.MessageOrBuilder
      Overrides:
      getDescriptorForType in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • getDefaultInstanceForType

      public SinkConfig.ConversionAction getDefaultInstanceForType()
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.MessageLiteOrBuilder
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.MessageOrBuilder
    • build

      Specified by:
      build in interface com.google.protobuf.Message.Builder
      Specified by:
      build in interface com.google.protobuf.MessageLite.Builder
    • buildPartial

      public SinkConfig.ConversionAction buildPartial()
      Specified by:
      buildPartial in interface com.google.protobuf.Message.Builder
      Specified by:
      buildPartial in interface com.google.protobuf.MessageLite.Builder
    • clone

      Specified by:
      clone in interface com.google.protobuf.Message.Builder
      Specified by:
      clone in interface com.google.protobuf.MessageLite.Builder
      Overrides:
      clone in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • setField

      public SinkConfig.ConversionAction.Builder setField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
      Specified by:
      setField in interface com.google.protobuf.Message.Builder
      Overrides:
      setField in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • clearField

      public SinkConfig.ConversionAction.Builder clearField(com.google.protobuf.Descriptors.FieldDescriptor field)
      Specified by:
      clearField in interface com.google.protobuf.Message.Builder
      Overrides:
      clearField in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • clearOneof

      public SinkConfig.ConversionAction.Builder clearOneof(com.google.protobuf.Descriptors.OneofDescriptor oneof)
      Specified by:
      clearOneof in interface com.google.protobuf.Message.Builder
      Overrides:
      clearOneof in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • setRepeatedField

      public SinkConfig.ConversionAction.Builder setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, int index, Object value)
      Specified by:
      setRepeatedField in interface com.google.protobuf.Message.Builder
      Overrides:
      setRepeatedField in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • addRepeatedField

      public SinkConfig.ConversionAction.Builder addRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
      Specified by:
      addRepeatedField in interface com.google.protobuf.Message.Builder
      Overrides:
      addRepeatedField in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • mergeFrom

      public SinkConfig.ConversionAction.Builder mergeFrom(com.google.protobuf.Message other)
      Specified by:
      mergeFrom in interface com.google.protobuf.Message.Builder
      Overrides:
      mergeFrom in class com.google.protobuf.AbstractMessage.Builder<SinkConfig.ConversionAction.Builder>
    • mergeFrom

    • isInitialized

      public final boolean isInitialized()
      Specified by:
      isInitialized in interface com.google.protobuf.MessageLiteOrBuilder
      Overrides:
      isInitialized in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • mergeFrom

      public SinkConfig.ConversionAction.Builder mergeFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Specified by:
      mergeFrom in interface com.google.protobuf.Message.Builder
      Specified by:
      mergeFrom in interface com.google.protobuf.MessageLite.Builder
      Overrides:
      mergeFrom in class com.google.protobuf.AbstractMessage.Builder<SinkConfig.ConversionAction.Builder>
      Throws:
      IOException
    • getMetricName

      public String getMetricName()
       The metric name to use for the stat.
       
      string metric_name = 2;
      Specified by:
      getMetricName in interface SinkConfig.ConversionActionOrBuilder
      Returns:
      The metricName.
    • getMetricNameBytes

      public com.google.protobuf.ByteString getMetricNameBytes()
       The metric name to use for the stat.
       
      string metric_name = 2;
      Specified by:
      getMetricNameBytes in interface SinkConfig.ConversionActionOrBuilder
      Returns:
      The bytes for metricName.
    • setMetricName

      public SinkConfig.ConversionAction.Builder setMetricName(String value)
       The metric name to use for the stat.
       
      string metric_name = 2;
      Parameters:
      value - The metricName to set.
      Returns:
      This builder for chaining.
    • clearMetricName

      public SinkConfig.ConversionAction.Builder clearMetricName()
       The metric name to use for the stat.
       
      string metric_name = 2;
      Returns:
      This builder for chaining.
    • setMetricNameBytes

      public SinkConfig.ConversionAction.Builder setMetricNameBytes(com.google.protobuf.ByteString value)
       The metric name to use for the stat.
       
      string metric_name = 2;
      Parameters:
      value - The bytes for metricName to set.
      Returns:
      This builder for chaining.
    • getStaticMetricLabelsList

      public List<KeyValue> getStaticMetricLabelsList()
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
      Specified by:
      getStaticMetricLabelsList in interface SinkConfig.ConversionActionOrBuilder
    • getStaticMetricLabelsCount

      public int getStaticMetricLabelsCount()
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
      Specified by:
      getStaticMetricLabelsCount in interface SinkConfig.ConversionActionOrBuilder
    • getStaticMetricLabels

      public KeyValue getStaticMetricLabels(int index)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
      Specified by:
      getStaticMetricLabels in interface SinkConfig.ConversionActionOrBuilder
    • setStaticMetricLabels

      public SinkConfig.ConversionAction.Builder setStaticMetricLabels(int index, KeyValue value)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • setStaticMetricLabels

      public SinkConfig.ConversionAction.Builder setStaticMetricLabels(int index, KeyValue.Builder builderForValue)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • addStaticMetricLabels

      public SinkConfig.ConversionAction.Builder addStaticMetricLabels(KeyValue value)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • addStaticMetricLabels

      public SinkConfig.ConversionAction.Builder addStaticMetricLabels(int index, KeyValue value)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • addStaticMetricLabels

      public SinkConfig.ConversionAction.Builder addStaticMetricLabels(KeyValue.Builder builderForValue)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • addStaticMetricLabels

      public SinkConfig.ConversionAction.Builder addStaticMetricLabels(int index, KeyValue.Builder builderForValue)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • addAllStaticMetricLabels

      public SinkConfig.ConversionAction.Builder addAllStaticMetricLabels(Iterable<? extends KeyValue> values)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • clearStaticMetricLabels

      public SinkConfig.ConversionAction.Builder clearStaticMetricLabels()
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • removeStaticMetricLabels

      public SinkConfig.ConversionAction.Builder removeStaticMetricLabels(int index)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • getStaticMetricLabelsBuilder

      public KeyValue.Builder getStaticMetricLabelsBuilder(int index)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • getStaticMetricLabelsOrBuilder

      public KeyValueOrBuilder getStaticMetricLabelsOrBuilder(int index)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
      Specified by:
      getStaticMetricLabelsOrBuilder in interface SinkConfig.ConversionActionOrBuilder
    • getStaticMetricLabelsOrBuilderList

      public List<? extends KeyValueOrBuilder> getStaticMetricLabelsOrBuilderList()
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
      Specified by:
      getStaticMetricLabelsOrBuilderList in interface SinkConfig.ConversionActionOrBuilder
    • addStaticMetricLabelsBuilder

      public KeyValue.Builder addStaticMetricLabelsBuilder()
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • addStaticMetricLabelsBuilder

      public KeyValue.Builder addStaticMetricLabelsBuilder(int index)
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • getStaticMetricLabelsBuilderList

      public List<KeyValue.Builder> getStaticMetricLabelsBuilderList()
       Static metric labels to use for the metric.
       
      repeated .opentelemetry.proto.common.v1.KeyValue static_metric_labels = 3;
    • setUnknownFields

      public final SinkConfig.ConversionAction.Builder setUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields)
      Specified by:
      setUnknownFields in interface com.google.protobuf.Message.Builder
      Overrides:
      setUnknownFields in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>
    • mergeUnknownFields

      public final SinkConfig.ConversionAction.Builder mergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields)
      Specified by:
      mergeUnknownFields in interface com.google.protobuf.Message.Builder
      Overrides:
      mergeUnknownFields in class com.google.protobuf.GeneratedMessageV3.Builder<SinkConfig.ConversionAction.Builder>