Class TraceConfig.Builder

  • All Implemented Interfaces:
    com.google.protobuf.Message.Builder, com.google.protobuf.MessageLite.Builder, com.google.protobuf.MessageLiteOrBuilder, com.google.protobuf.MessageOrBuilder, TraceConfigOrBuilder, Cloneable
    Enclosing class:
    TraceConfig

    public static final class TraceConfig.Builder
    extends com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
    implements TraceConfigOrBuilder
     Global configuration of the trace service. All fields must be specified, or
     the default (zero) values will be used for each type.
     
    Protobuf type opentelemetry.proto.trace.v1.TraceConfig
    • Method Detail

      • getDescriptor

        public static final com.google.protobuf.Descriptors.Descriptor getDescriptor()
      • internalGetFieldAccessorTable

        protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
        Specified by:
        internalGetFieldAccessorTable in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • clear

        public TraceConfig.Builder clear()
        Specified by:
        clear in interface com.google.protobuf.Message.Builder
        Specified by:
        clear in interface com.google.protobuf.MessageLite.Builder
        Overrides:
        clear in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • getDescriptorForType

        public com.google.protobuf.Descriptors.Descriptor getDescriptorForType()
        Specified by:
        getDescriptorForType in interface com.google.protobuf.Message.Builder
        Specified by:
        getDescriptorForType in interface com.google.protobuf.MessageOrBuilder
        Overrides:
        getDescriptorForType in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • getDefaultInstanceForType

        public TraceConfig getDefaultInstanceForType()
        Specified by:
        getDefaultInstanceForType in interface com.google.protobuf.MessageLiteOrBuilder
        Specified by:
        getDefaultInstanceForType in interface com.google.protobuf.MessageOrBuilder
      • build

        public TraceConfig build()
        Specified by:
        build in interface com.google.protobuf.Message.Builder
        Specified by:
        build in interface com.google.protobuf.MessageLite.Builder
      • buildPartial

        public TraceConfig buildPartial()
        Specified by:
        buildPartial in interface com.google.protobuf.Message.Builder
        Specified by:
        buildPartial in interface com.google.protobuf.MessageLite.Builder
      • clone

        public TraceConfig.Builder clone()
        Specified by:
        clone in interface com.google.protobuf.Message.Builder
        Specified by:
        clone in interface com.google.protobuf.MessageLite.Builder
        Overrides:
        clone in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • setField

        public TraceConfig.Builder setField​(com.google.protobuf.Descriptors.FieldDescriptor field,
                                            Object value)
        Specified by:
        setField in interface com.google.protobuf.Message.Builder
        Overrides:
        setField in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • clearField

        public TraceConfig.Builder clearField​(com.google.protobuf.Descriptors.FieldDescriptor field)
        Specified by:
        clearField in interface com.google.protobuf.Message.Builder
        Overrides:
        clearField in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • clearOneof

        public TraceConfig.Builder clearOneof​(com.google.protobuf.Descriptors.OneofDescriptor oneof)
        Specified by:
        clearOneof in interface com.google.protobuf.Message.Builder
        Overrides:
        clearOneof in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • setRepeatedField

        public TraceConfig.Builder setRepeatedField​(com.google.protobuf.Descriptors.FieldDescriptor field,
                                                    int index,
                                                    Object value)
        Specified by:
        setRepeatedField in interface com.google.protobuf.Message.Builder
        Overrides:
        setRepeatedField in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • addRepeatedField

        public TraceConfig.Builder addRepeatedField​(com.google.protobuf.Descriptors.FieldDescriptor field,
                                                    Object value)
        Specified by:
        addRepeatedField in interface com.google.protobuf.Message.Builder
        Overrides:
        addRepeatedField in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • mergeFrom

        public TraceConfig.Builder mergeFrom​(com.google.protobuf.Message other)
        Specified by:
        mergeFrom in interface com.google.protobuf.Message.Builder
        Overrides:
        mergeFrom in class com.google.protobuf.AbstractMessage.Builder<TraceConfig.Builder>
      • isInitialized

        public final boolean isInitialized()
        Specified by:
        isInitialized in interface com.google.protobuf.MessageLiteOrBuilder
        Overrides:
        isInitialized in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • mergeFrom

        public TraceConfig.Builder mergeFrom​(com.google.protobuf.CodedInputStream input,
                                             com.google.protobuf.ExtensionRegistryLite extensionRegistry)
                                      throws IOException
        Specified by:
        mergeFrom in interface com.google.protobuf.Message.Builder
        Specified by:
        mergeFrom in interface com.google.protobuf.MessageLite.Builder
        Overrides:
        mergeFrom in class com.google.protobuf.AbstractMessage.Builder<TraceConfig.Builder>
        Throws:
        IOException
      • hasConstantSampler

        public boolean hasConstantSampler()
        .opentelemetry.proto.trace.v1.ConstantSampler constant_sampler = 1;
        Specified by:
        hasConstantSampler in interface TraceConfigOrBuilder
        Returns:
        Whether the constantSampler field is set.
      • clearConstantSampler

        public TraceConfig.Builder clearConstantSampler()
        .opentelemetry.proto.trace.v1.ConstantSampler constant_sampler = 1;
      • getConstantSamplerBuilder

        public ConstantSampler.Builder getConstantSamplerBuilder()
        .opentelemetry.proto.trace.v1.ConstantSampler constant_sampler = 1;
      • hasTraceIdRatioBased

        public boolean hasTraceIdRatioBased()
        .opentelemetry.proto.trace.v1.TraceIdRatioBased trace_id_ratio_based = 2;
        Specified by:
        hasTraceIdRatioBased in interface TraceConfigOrBuilder
        Returns:
        Whether the traceIdRatioBased field is set.
      • clearTraceIdRatioBased

        public TraceConfig.Builder clearTraceIdRatioBased()
        .opentelemetry.proto.trace.v1.TraceIdRatioBased trace_id_ratio_based = 2;
      • getTraceIdRatioBasedBuilder

        public TraceIdRatioBased.Builder getTraceIdRatioBasedBuilder()
        .opentelemetry.proto.trace.v1.TraceIdRatioBased trace_id_ratio_based = 2;
      • hasRateLimitingSampler

        public boolean hasRateLimitingSampler()
        .opentelemetry.proto.trace.v1.RateLimitingSampler rate_limiting_sampler = 3;
        Specified by:
        hasRateLimitingSampler in interface TraceConfigOrBuilder
        Returns:
        Whether the rateLimitingSampler field is set.
      • clearRateLimitingSampler

        public TraceConfig.Builder clearRateLimitingSampler()
        .opentelemetry.proto.trace.v1.RateLimitingSampler rate_limiting_sampler = 3;
      • getRateLimitingSamplerBuilder

        public RateLimitingSampler.Builder getRateLimitingSamplerBuilder()
        .opentelemetry.proto.trace.v1.RateLimitingSampler rate_limiting_sampler = 3;
      • getMaxNumberOfAttributes

        public long getMaxNumberOfAttributes()
         The global default max number of attributes per span.
         
        int64 max_number_of_attributes = 4;
        Specified by:
        getMaxNumberOfAttributes in interface TraceConfigOrBuilder
        Returns:
        The maxNumberOfAttributes.
      • setMaxNumberOfAttributes

        public TraceConfig.Builder setMaxNumberOfAttributes​(long value)
         The global default max number of attributes per span.
         
        int64 max_number_of_attributes = 4;
        Parameters:
        value - The maxNumberOfAttributes to set.
        Returns:
        This builder for chaining.
      • clearMaxNumberOfAttributes

        public TraceConfig.Builder clearMaxNumberOfAttributes()
         The global default max number of attributes per span.
         
        int64 max_number_of_attributes = 4;
        Returns:
        This builder for chaining.
      • getMaxNumberOfTimedEvents

        public long getMaxNumberOfTimedEvents()
         The global default max number of annotation events per span.
         
        int64 max_number_of_timed_events = 5;
        Specified by:
        getMaxNumberOfTimedEvents in interface TraceConfigOrBuilder
        Returns:
        The maxNumberOfTimedEvents.
      • setMaxNumberOfTimedEvents

        public TraceConfig.Builder setMaxNumberOfTimedEvents​(long value)
         The global default max number of annotation events per span.
         
        int64 max_number_of_timed_events = 5;
        Parameters:
        value - The maxNumberOfTimedEvents to set.
        Returns:
        This builder for chaining.
      • clearMaxNumberOfTimedEvents

        public TraceConfig.Builder clearMaxNumberOfTimedEvents()
         The global default max number of annotation events per span.
         
        int64 max_number_of_timed_events = 5;
        Returns:
        This builder for chaining.
      • getMaxNumberOfAttributesPerTimedEvent

        public long getMaxNumberOfAttributesPerTimedEvent()
         The global default max number of attributes per timed event.
         
        int64 max_number_of_attributes_per_timed_event = 6;
        Specified by:
        getMaxNumberOfAttributesPerTimedEvent in interface TraceConfigOrBuilder
        Returns:
        The maxNumberOfAttributesPerTimedEvent.
      • setMaxNumberOfAttributesPerTimedEvent

        public TraceConfig.Builder setMaxNumberOfAttributesPerTimedEvent​(long value)
         The global default max number of attributes per timed event.
         
        int64 max_number_of_attributes_per_timed_event = 6;
        Parameters:
        value - The maxNumberOfAttributesPerTimedEvent to set.
        Returns:
        This builder for chaining.
      • clearMaxNumberOfAttributesPerTimedEvent

        public TraceConfig.Builder clearMaxNumberOfAttributesPerTimedEvent()
         The global default max number of attributes per timed event.
         
        int64 max_number_of_attributes_per_timed_event = 6;
        Returns:
        This builder for chaining.
      • getMaxNumberOfLinks

        public long getMaxNumberOfLinks()
         The global default max number of link entries per span.
         
        int64 max_number_of_links = 7;
        Specified by:
        getMaxNumberOfLinks in interface TraceConfigOrBuilder
        Returns:
        The maxNumberOfLinks.
      • setMaxNumberOfLinks

        public TraceConfig.Builder setMaxNumberOfLinks​(long value)
         The global default max number of link entries per span.
         
        int64 max_number_of_links = 7;
        Parameters:
        value - The maxNumberOfLinks to set.
        Returns:
        This builder for chaining.
      • clearMaxNumberOfLinks

        public TraceConfig.Builder clearMaxNumberOfLinks()
         The global default max number of link entries per span.
         
        int64 max_number_of_links = 7;
        Returns:
        This builder for chaining.
      • getMaxNumberOfAttributesPerLink

        public long getMaxNumberOfAttributesPerLink()
         The global default max number of attributes per span.
         
        int64 max_number_of_attributes_per_link = 8;
        Specified by:
        getMaxNumberOfAttributesPerLink in interface TraceConfigOrBuilder
        Returns:
        The maxNumberOfAttributesPerLink.
      • setMaxNumberOfAttributesPerLink

        public TraceConfig.Builder setMaxNumberOfAttributesPerLink​(long value)
         The global default max number of attributes per span.
         
        int64 max_number_of_attributes_per_link = 8;
        Parameters:
        value - The maxNumberOfAttributesPerLink to set.
        Returns:
        This builder for chaining.
      • clearMaxNumberOfAttributesPerLink

        public TraceConfig.Builder clearMaxNumberOfAttributesPerLink()
         The global default max number of attributes per span.
         
        int64 max_number_of_attributes_per_link = 8;
        Returns:
        This builder for chaining.
      • setUnknownFields

        public final TraceConfig.Builder setUnknownFields​(com.google.protobuf.UnknownFieldSet unknownFields)
        Specified by:
        setUnknownFields in interface com.google.protobuf.Message.Builder
        Overrides:
        setUnknownFields in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>
      • mergeUnknownFields

        public final TraceConfig.Builder mergeUnknownFields​(com.google.protobuf.UnknownFieldSet unknownFields)
        Specified by:
        mergeUnknownFields in interface com.google.protobuf.Message.Builder
        Overrides:
        mergeUnknownFields in class com.google.protobuf.GeneratedMessageV3.Builder<TraceConfig.Builder>